What backflow is and why it matters
Water normally flows one way, from the mains into your property. Backflow happens when it reverses. This can occur when pressure in the mains drops, for example during a main break or heavy firefighting use, which can siphon water back from a property. It can also happen when pressure inside a property is higher than the mains, such as from a pump or boiler. If that reversed water has been in contact with chemicals, irrigation systems, fire service water or industrial processes, it can contaminate the drinking water supply for everyone nearby. Backflow prevention devices are fitted to stop that happening. Because they protect public health, testable devices must be kept in working order and tested regularly.
Which properties have testable devices
Testable backflow devices are common on commercial and industrial properties. Examples include factories, workshops, medical and dental practices, car washes, cafes and restaurants with certain equipment, and buildings with fire sprinkler or hydrant systems. Properties with irrigation systems, pools with chemical dosing, or rainwater tanks connected to the mains supply may also need protection. If your business changes what it does on site, the hazard rating and the device needed may change too.
The type of device depends on the level of hazard. Reduced pressure zone devices are used for higher hazard situations, while double check valves suit lower hazards. Many homes have only a non-testable dual check valve at the meter, or no separate device at all, and these don't need annual testing. If you aren't sure whether your property has a testable device, we can check for you. Choosing the right device for the hazard is part of keeping the site compliant.
What happens during a backflow test
A backflow test checks that each part of the device works as it should. Using a calibrated test kit, the tester measures pressure differences across the check valves and confirms that relief valves open and shut correctly. The water supply through the device is briefly turned off during the test, so we arrange a time that suits your business. The test itself is usually quick.
If the device passes, we record the results and provide you with a test report. If it fails, we explain which part failed and why. In many cases the device can be serviced on the spot by cleaning or replacing internal parts, then retested. You get a written price before any repairs. We work around your trading hours where we can, and we let staff know before the water goes off.
Annual testing and Queensland requirements
In Queensland, the owner of a property with a testable backflow prevention device is responsible for having it tested at least once a year by a licensed tester. Test results need to be reported to the relevant authority. Keeping up with testing helps protect the water supply and keeps your property compliant. Missing a test can lead to follow-up from the authority, so it is worth putting the date in your calendar. Property managers and body corporates often manage several devices across different sites. We can help you keep track of when each device is due.
When a device fails or needs replacing
Backflow devices have rubber seals, springs and moving parts that wear over time. Debris from the mains can also stop valves closing properly. A failed test usually means one of these parts needs cleaning or replacing. If a device is old, damaged or parts are hard to get, replacing it may be the better choice. Replacement devices must suit the hazard rating of the site and be installed by a licensed plumber. After installation, a new testable device needs to be tested before it goes into service. We can handle the replacement, testing and paperwork in one visit where possible.
Looking after your backflow device between tests
Keep the device accessible, not buried behind stored goods or overgrown plants, so it can be tested easily. Protect outdoor devices from damage by vehicles and mowers. If you notice water discharging from a relief valve, a leak or a sudden drop in pressure, call us rather than waiting for the next test. Constant discharge can mean the device has failed or there is a pressure problem on the site. Make sure staff know what the device is so it isn't turned off or tampered with.